Search results for "blood [Hashimoto Disease]"
showing 10 items of 836 documents
Random allogeneic blood transfusion in pigs: characterisation of a novel experimental model.
2019
BackgroundOrgan cross-talk describes interactions between a primary affected organ and a secondarily injured remote organ, particularly in lung-brain interactions. A common theory is the systemic distribution of inflammatory mediators that are released by the affected organ and transferred through the bloodstream. The present study characterises the baseline immunogenic effects of a novel experimental model of random allogeneic blood transfusion in pigs designed to analyse the role of the bloodstream in organ cross-talk.MethodsAfter approval of the State and Institutional Animal Care Committee, 20 anesthetized pig were randomized in a donor and an acceptor (eachn = 8): the acceptor animals …
Intraoperative transfusion practices in Europe
2016
PubMed: 26787795
Genotypic and Phenotypic Characteristics of Acute Promyelocytic Leukemia Translocation Variants.
2020
Acute promyelocytic leukemia (APL) is a special disease entity of acute myeloid leukemia (AML). The clinical use of all-trans retinoic acid (ATRA) has transformed APL into the most curable form of AML. The majority of APL cases are characterized by the fusion gene PML-RARA. Although the PML-RARA fusion gene can be detected in almost all APL cases, translocation variants of APL have been reported. To date, this is the most comprehensive review of these translocations, discussing 15 different variants. Reviewed genes involved in APL variants include: ZBTB16, NPM, NuMA, STAT5b, PRKAR1A, FIP1L1, BCOR, NABP1, TBLR1, GTF2I, IRF2BP2, FNDC3B, ADAMDTS17, STAT3, and TFG. The genotypic and phenotypic …
Comparison between a guaiac and three immunochemical faecal occult blood tests in screening for colorectal cancer
2012
Abstract Background The aim of this study was to compare the performance of the guaiac-based faecal occult blood test (G-FOBT), with that of three immunochemical faecal occult blood tests (I-FOBT) which allow automatic interpretation. Patients and methods Under the French organised screening programme, 85,149 average-risk individuals aged 50–74 participating in the third screening round, performed both the G-FOBT (Hemoccult-II test) and one of the I-FOBTs: FOB-Gold, Magstream and OC-Sensor. Results Given the chosen threshold, the positivity ratio between the different I-FOBTs and the G-FOBT was 2.4 for FOB-Gold, 2.0 for Magstream and 2.2 for OC-Sensor (P = 0.17). The three I-FOBTs were supe…
Immunochemical faecal occult blood tests are superior to guaiac-based tests for the detection of colorectal neoplasms
2008
The aim of this study was to compare the performance of a guaiac-based faecal occult blood test (G-FOBT) with that of an immunochemical faecal occult blood test (I-FOBT). A total of 17,215 average risk individuals aged 50 to 74 enrolled in a population-based organised screening programme and performed a 3-day G-FOBT and a 2-day I-FOBT simultaneously. Among participants, 3.1% were found positive for the G-FOBT and 6.9% for the I-FOBT (p<10(-4)). Among the 1205 participants who tested positive and underwent a colonoscopy, the number of detected cancers and advanced adenomas was respectively 2.6 times higher and 3.5 times higher with the I-FOBT than with the G-FOBT. The positive predictive val…
Faecal immunochemical tests: A valuable tool for colorectal cancer screening
2012
Colorectal cancer is a major health problem in industrialized ountries and fulfils the conditions required to justifymass screenng of the general population. Population-based controlled studies erformed in Europe have shown that guaiac faecal occult blood esting (G-FOBT) followed by colonoscopy to detect the cause of leeding can reduce colorectal cancer mortality [1]. Nearly all pubished studies evaluated the Hemoccult II (Beckman Coulter Inc., ea, USA) faecal occult blood test. Screening for colorectal caner using FOBT has, therefore, been included in the European Code gainst Cancer and has been endorsed by the European Commision [2]. Despite its high specificity, Hemoccult has been critic…
Twelve-Month Estrogen Levels in Premenopausal Women With Hormone Receptor–Positive Breast Cancer Receiving Adjuvant Triptorelin Plus Exemestane or Ta…
2016
Purpose To describe estradiol (E2), estrone (E1), and estrone sulfate (E1S) levels during the first year of monthly triptorelin plus exemestane or tamoxifen and to assess possible suboptimal suppression while receiving exemestane plus triptorelin. Patients and Methods Premenopausal patients with early breast cancer on the Suppression of Ovarian Function Trial who selected triptorelin as the ovarian suppression method and were randomly assigned to exemestane plus triptorelin or tamoxifen plus triptorelin were enrolled until the target population of 120 patients was reached. Blood sampling time points were 0, 3, 6, 12, 18, 24, 36, and 48 months. Serum estrogens were measured with a highly sen…
Antibodies to hepatitis B core antigen in blood donors screened for alanine aminotransferase level and hepatitis non-A, non-B in recipients.
1988
Four-hundred and seventeen patients undergoing open-heart surgery were followed for more than 9 months after transfusion. All 2270 blood units transfused had alanine aminotransferase levels less than or equal to 30 U/l. Blood units positive for antibodies to hepatitis B core antigen (anti-HBc) were more frequently associated with recipient hepatitis non-A, non-B (HNANB) (13.7%) than anti-HBc-negative units (4.2%) (p less than 0.001). The frequency of HNANB among recipients of at least 1 anti-HBc-positive blood unit (8/79, 10.1%) was fivefold greater than among recipients of exclusively anti-HBc-negative blood units (7/338, 2.1%) (p less than 0.01). In this study the exclusion of donors posi…
A new principle to normalize plasma concentrations allowing single-sample clearance determinations in both children and adults.
1992
A sufficiently accurate quantification of renal function requiring only one plasma sample without an additional gamma-camera study has, until now, only been possible in adults. A new principle will be presented here allowing the universal application of known algorithms, regardless of the clearance substance used, by normalizing the plasma concentrations with respect to the individual body dimensions of the patients - for infants as well as for adults. In this respect, algorithms are developed for clearance determinations using technetium-99m mercaptoacetyltriglycine (99mTc-MAG3), which are based on steady-state studies as the reference. They allow the calculation of quantitative clearance …
Clinical-anamnestic and instrumental data in outpatients suffering from venous disease
1995
The authors studied 200 consecutive outpatients with symptoms due to venous disease of the lower limbs. All the patients underwent anamnestic, clinical and instrumental evaluation (c.w. Doppler velocimetry and strain-gauge plethysmography). The results of this study showed that some anamnestic and clinical data are significantly related to venous disease detected by instrumental techniques. The superficial and deep vein hypertension were, instead, correlated to oral contraceptive use.